Graco Ultra Max II 1095

Manuals, pump repair kits, parts and troubleshooting for the Graco Ultra Max II 1095, from Graco's own manuals and parts lists.

Find your version

Find the model number on your sprayer's data plate and match it to the first column. Each row shows the pump Graco's Parts Book lists for that model and the pump's repair kit.

Repair kits listed

Graco Ultra Max II 1095 versions
Model numberParts Book titleSeriesYearsPump and repair kit
16W8991095, Ultra Max II, Standard, Hi-Boy3/2014-1/2019
  • Pump 16Y706 Standard Threaded Pump (Standard)Repair kit 248213 $108.58
16W9001095, Ultra Max II, ProContractor, Hi-Boy3/2014-1/2019
  • Pump 16X419 $919.80 ProContractor ProConnect II Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16X420 ProConnect II Max Life Pump Kit (Alternate)Repair kit 17K162 $148.88
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Upgrade)Repair kit 17K162 $148.88
16W9011095, Ultra Max II, IronMan, Hi-Boy3/2014-1/2019
  • Pump 16X420 ProConnect II Max Life Pump Kit (Standard)Repair kit 17K162 $148.88
  • Pump 16X419 $919.80 ProContractor ProConnect II Pump Kit (Alternate)Repair kit 248213 $108.58
  • Pump 17H826 $1,831.20 ProConnect II MaxLife Extreme (Upgrade)Repair kit 17K162 $148.88
16X8811095, Ultra Max, Standard, AP Multicord, 230V
  • Pump 16X419 $919.80 ProContractor ProConnect II Pump Kit (Standard)Repair kit 248213 $108.58
16Y8321095, Ultra Max II, ProContractor, Hi-Boy, AP Multicord, 230V
  • Pump 16X419 $919.80 ProContractor ProConnect II Pump Kit (Standard)Repair kit 248213 $108.58
16Y8711095, Ultra Max II, IronMan, AP Multicord, 230V1/2014-1/2019
  • Pump 16X420 ProConnect II Max Life Pump Kit (Standard)Repair kit 17K162 $148.88
17E583Ultra Max II 1095 Standard Hi-Boy1/2019-/
  • Pump 16Y706 Standard Threaded Pump (Standard)Repair kit 248213 $108.58
17E585Ultra Max II 1095 ProContractor Hi-Boy1/2019-/
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Standard)Repair kit 17K162 $148.88
17E586Ultra Max II 1095 IronMan Hi-Boy1/2019-/
  • Pump 17H826 $1,831.20 ProConnect II MaxLife Extreme (Standard)Repair kit 17K162 $148.88
17E620Ultra Max II 1095 Standard Hi-Boy - AP1/2019-/
  • Pump 16Y706 Standard Threaded Pump (Standard)Repair kit 248213 $108.58
17E621Ultra Max II 1095 ProContractor Hi-Boy - AP1/2019-/
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Standard)Repair kit 17K162 $148.88
17E622Ultra Max II 1095 ProContractor Hi-Boy - Japan1/2019-/
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Standard)Repair kit 17K162 $148.88
Show all 63 models
Graco Ultra Max II 1095 versions, continued
Model numberParts Book titleSeriesYearsPump and repair kit
17E623Ultra Max II 1095 IronMan Hi-Boy - AP1/2019-/
  • Pump 17H826 $1,831.20 ProConnect II MaxLife Extreme (Standard)Repair kit 17K162 $148.88
17E646Ultra Max II 1095 Standard Hi-Boy - CEE1/2019-/
  • Pump 16Y706 Standard Threaded Pump (Standard)Repair kit 248213 $108.58
17E647Ultra Max II 1095 ProContractor Hi-Boy - CEE1/2019-/
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Standard)Repair kit 17K162 $148.88
17E648Ultra Max II 1095 ProContractor Hi-Boy - Multicord1/2019-/
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Standard)Repair kit 17K162 $148.88
17E650Ultra Max II 1095 IronMan Hi-Boy - CEE1/2019-/
  • Pump 17H826 $1,831.20 ProConnect II MaxLife Extreme (Standard)Repair kit 17K162 $148.88
2321501095 Ultra Max (Non-Display)7/1997-10/2001
  • Pump 239923 Displacement PumpRepair kit 248212 $90.76
2321511095 Ultra Max (Non-Display) Bare7/1997-10/2001
  • Pump 239923 Displacement PumpRepair kit 248212 $90.76
2450301095 Ultra Max (Display)5/2000-5/2004
  • Pump 244197 Displacement PumpRepair kit 248212 $90.76
245032Ultra Max 1095A5/2000-5/2004
  • Pump 244197 Displacement Pump (Standard)Repair kit 248212 $90.76
2480341095, Ultra Max II, Premium, Hi-Boy10/2003-1/2006
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2480391095, Ultra Max II, Standard, Hi-Boy10/2003-1/2006
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2480441095 HI-BOY, UMAX, EUROPE CEE 7/7
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2480481095 HI-BOY, EUROPE MLT CORD
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2480511095 HI-BOY, UMAX, UK 110V
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2480561095 HI-BOY, UMAX, JAPAN
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2480601095 HI-BOY, 240V ASIA
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2485951095 HI-BOY, 240V, AUST
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
2496511095, Ultra Max II, Standard, Hi-BoyB6/2009-1/2010
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496511095, Ultra Max II, Standard, Hi-BoyA9/2005-6/2009
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496531095, Ultra Max II, Premium, Hi-BoyB6/2009-1/2010
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496531095, Ultra Max II, Premium, Hi-BoyA9/2005-6/2009
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496671095 HI-BOY, UMAX, EUROPE CEE 7/7
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496721095 HI-BOY, EUROPE MLT CORD
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496751095 HI-BOY, UMAX, UK 110V
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496801095 HI-BOY, UMAX, JAPAN
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496841095 HI-BOY, 240V ASIA
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2496881095 HI-BOY, 240V, AUST
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2570401095 Platinum, Euro CEE 7/7
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2570411095 Platinum, Multi-cord
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2570421095 Platinum, UK
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2587271095, Ultra Max II, Premium, Hi-Boy1/2010-12/2013
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2587281095, Ultra Max II, Standard, Hi-Boy1/2010-12/2013
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2588831095, Ultra Max II, Premium, Hi-Boy, Japan/Taiwan3/2011-12/2014
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2588841095, Ultra Max II, Standard, Hi-Boy, Aus/China3/2011-1/2019
  • Pump 287513 Pump KitRepair kit 248213 $108.58
2588861095, Ultra Max II, Premium, Hi-Boy, Aus/China3/2011-12/2014
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8241501095 ULTIMATE MX (Non-Display)8/1997-2/2001
  • Pump 239923 Displacement PumpRepair kit 248212 $90.76
8250301095 ULTIMATE MX (Display)6/2000-5/2004
  • Pump 244197 Displacement PumpRepair kit 248212 $90.76
8260441095, Ultimate MX II, Premium, Hi-Boy10/2003-1/2006
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
8260501095, Ultimate MX II, Standard, Hi-Boy10/2003-1/2006
  • Pump 248205 Standard Threaded Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16Y706 Standard Threaded Pump (Alternate)Repair kit 248213 $108.58
8260731095, Ultimate MX II, Standard, Hi-BoyB6/2009-1/2010
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8260731095, Ultimate MX II, Standard, Hi-BoyA9/2005-6/2009
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8260741095, Ultimate MX II, Premium, Hi-BoyB6/2009-1/2010
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8260741095, Ultimate MX II, Premium, Hi-BoyA9/2005-6/2009
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8261301095, Ultimate MX II, Premium, Hi-Boy1/2010-12/2013
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8261311095, Ultimate MX II, Standard, Hi-Boy1/2010-12/2013
  • Pump 287513 Pump KitRepair kit 248213 $108.58
8261821095, Ultimate MX II, Standard, Hi-Boy3/2014-1/2019
  • Pump 16Y706 Standard Threaded PumpRepair kit 248213 $108.58
8261831095, Ultimate MX II, ProContractor, Hi-Boy3/2014-1/2019
  • Pump 16X419 $919.80 ProContractor ProConnect II Pump Kit (Standard)Repair kit 248213 $108.58
  • Pump 16X420 ProConnect II Max Life Pump Kit (Alternate)Repair kit 17K162 $148.88
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Upgrade)Repair kit 17K162 $148.88
8261841095, Ultimate MX II, IronMan, Hi-Boy3/2014-1/2019
  • Pump 16X420 ProConnect II Max Life Pump KitRepair kit 17K162 $148.88
  • Pump 16X419 $919.80 ProContractor ProConnect II Pump Kit (Alternate)Repair kit 248213 $108.58
  • Pump 17H826 $1,831.20 ProConnect II MaxLife Extreme (Upgrade)Repair kit 17K162 $148.88
826227Ultimate MX II 1095 Standard Hi-Boy1/2019-/
  • Pump 16Y706 Standard Threaded Pump (Standard)Repair kit 248213 $108.58
826228Ultimate MX II 1095 Procontractor Hi-Boy1/2019-/
  • Pump 17H824 $1,528.80 ProConnect II MaxLife Vortex Pump (Standard)Repair kit 17K162 $148.88
826229Ultimate MX II 1095 IronMan Hi-Boy1/2019-/
  • Pump 17H826 $1,831.20 ProConnect II MaxLife Extreme (Standard)Repair kit 17K162 $148.88

Manuals

Links open the manufacturer's official copy.

Parts we sell for the Graco Ultra Max II 1095

Filters (11)
Gun (5)
Hose (7)
  • 15D049 HOSE,CPLD, 1/4" X15.75"
  • 15D360 HOSE, COUPLED, 3/8 X 18.25
  • 16X904 HOSE, COUPLED, 3/8" ID
  • 240794 HOSE, COUPLED, 1/4 X 50'
  • 240797 HOSE, COUPLED, 3/8 X 50'
  • 24V029 KIT,REPAIR,HOSE,COUPLED, 1/2"
  • 288658 KIT, HOSE, COUPLED
Kit (9)
  • 17D888 KIT, REPLACEMENT, POTENTIOMETER
  • 17Y297 KIT, REPAIR, CARTRIDGE, PC GUN
  • 17Y466 KIT, TRIGGER, CONTRACTOR PC
  • 235474 KIT, REPAIR GUN
  • 244240 KIT, REPAIR, RETURN LINE, HI
  • 248214 KIT, REPAIR, INTAKE TUBE
  • 248215 KIT, REPAIR, INTAKE TUBE
  • 248217 KIT, REPAIR, DRAIN HOSE
  • 287952 KIT,REPAIR,DRAIN HOSE
Motor (8)
Packing (5)
Pump (4)
  • 16X419 KIT,PUMP,5900 PCII
  • 17H824 KIT, PUMP, 5900PCII, MAXLIFE
  • 17H826 KIT, PUMP, 5900PCII, IRONMAN
  • 248213 KIT, REPAIR,PUMP,1095/1595
Tip (5)
  • 17Y042 CONTRACTOR PC GUN,RAC X,LTX,PKGD
  • 17Y043 CONTRACTOR PC GUN,RAC X,LP,PKGD
  • 286517 RAC 5 TIP,SPRAY
  • 288420 CONTRACTOR GUN,RAC X(PKGD)
  • LTX517 RAC X LTX TIP,SPRAY,517
Valve (4)
  • 235014 KIT, REPLACEMENT, DRAIN VALVE
  • 245103 KIT REPAIR, DRAIN VALVE
  • 24B156 VALVE, PRIME, HD, THREAD PATCH
  • 257352 KIT, REPAIR, PRIME VALVE, HD
Other parts (12)

Troubleshooting from the manual

Motor won't operate
  1. 1. Check digital display for error codes on spray- ers with digital displays or motor control board inside SmartControl for blinking LED on spray- ers without digital displays 1. If an error code (E=0X) is displayed or LED is blinking, go to page 18 for error code diag- nostics. If not continue.
  2. 2. Make sure digital display is connected. If noth- ing is displayed, check power cord, power switch and all power connections for continuity. Check building circuit power. 2. Tighten any loose power connections. Re- place power switch, power cord or extension cords if damaged. Reset circuit breaker if tripped.
  3. 3. Check pressure control knob setting. Motor will not run if pressure control knob is at minimum setting. 3. Increase pressure setting
  4. 4. With drain valve open and pressure control knob set to maximum, check if there is a light blinking next to either psi , bar , or MPa a. If light is blinking, control board is commanding motor to run and prob- lem is most likely motor or motor wiring. b. If light is not blinking, control board, control board wiring, potentiometer or transducer is most likely cause. 4. Based on results of this test, investigate for possible wiring, motor, control, transducer or potentiometer problems in the following steps

From 309251 rev E, page 5

Motor
  1. 1. Connections at control board and brushes 1. Repair any loose connections
  2. 2. Brushes worn. Length must be 1/2 in. minimum. Check both sides. 2. Replace brushes. Page 9.
  3. 3. Broken or misaligned brush springs 3. Realign or replace springs
  4. 4. Brushes or springs binding in brush holder 4. Clean brush holder and align brush leads for free movement
  5. 5. Check for armature short using an armature tester (growler) or perform spin test. Page 9. 5. Replace motor
  6. 6. Check motor armature commutator for burn spots or other damage 6. Remove motor and have motor shop resur- face commutator if possible. Page 22.

From 309251 rev E, page 6

Control board or wiring
  1. 1. Loose control board wiring 1. Repair any loose connections
  2. 2. Damaged control board 2. Replace control board

From 309251 rev E, page 6

Control/sensor
  1. 1. Potentiometer damaged 1. Replace potentiometer
  2. 2. Pressure transducer damaged 2. Replace pressure transducer

From 309251 rev E, page 6

Building circuit breaker opens CAUTION Any short in any part of the motor power circuit will cause the control circuit to inhibit sprayer operation. Correctly
  1. 1. Current limit exceeded 1. Switch to another circuit with less load. If sprayer has a 15/20A or 10/12A switch, change to lower value.
  2. 2. All electrical wiring for damaged insulation, and all terminals for loose fit or damage. Also wires between pressure control and motor. See page 22. 2. Repair or replace any damaged wiring or terminals. Securely reconnect all wires.
  3. 3. For missing inspection plate gasket (see page 22), bent terminals or other metal to metal con- tact points which could cause a short. 3. Correct faulty conditions.
  4. 4. Motor armature for shorts. Use an armature tester (growler) or perform spin test. See page 9. Inspect windings for burns. 4. Replace motor. See page 22.

From 309251 rev E, page 8

diagnose and repair all shorts before checking and replac- ing control board.
  1. 5. Motor control board (35) by performing motor control board diagnostics on page 16. If diag- nostics indicate, substitute with a good board. CAUTION: Do not perform this check until mo- tor armature is determined to be good. A bad motor armature can burn out a good board. 5. Replace with a new pressure control board (35). See page 16.

From 309251 rev E, page 8

Display reads all 8's
  1. Switches on back of display are set incorrectly. Set the four switches psi, bar, MPa and liters/gallons to proper settings for your sprayer. Fig. 13, page 16.

From 309251 rev E, page 8

Pump output is low (continued)
  1. Pump throat packings are worn. Tighten packing nut/wet cup. If leakage continues, replace packings; see pump manual. Also check piston valve seat for hardened paint or nicks and replace if necessary. Tighten packing nut/wet-cup.
  2. Intake valve ball is packed with material Clean intake valve; see pump manual.
  3. Pressure setting is too low Turn Pressure Control Knob clockwise to increase pressure.
  4. Material is too thick for asmall diameter Hose,orHose is too long. Use larger diameter Hose and/or reduce overall length of Hose.
  5. Amp switch is on low setting. (10A or 15A setting) Switch to 16A or 20A setting.

From 3A6342 rev G, page 37

Fluid is spitting from Spray Gun
  1. Tip is partially clogged Refer to Clear Spray Tip Clog , page 25.
  2. Material supply low, orairwas not properly purged during priming. Refill fluid supply. Refer to FillPump(Prime Pump) , page 21. Then Fill Spray Gun and Hose , page 21. Check fluid supply often to prevent running pump dry.

From 3A6342 rev G, page 37

Pump is difficult to prime
  1. Intake valve is stuck to seat. Removefootvalve.Cleanandinspectintake valve.
  2. Suction tube o-ring on foot valve is damaged or missing. Replace Suction Tube o-ring.
  3. Air in pump Refer to FillPump (PrimePump) , page 21. Then Fill Spray Gun and Hose , page 21.
  4. Intake valve is leaking Clean intake valve. Be sure ball seat is not nicked or worn and that ball seats well. Reassemble valve.
  5. Pump packings are worn Replace pump packings; see pump manual.

From 3A6342 rev G, page 37

Motor does not run
  1. Pressure Control Knob is set too low Increase pressure by turning Pressure Control Knob clockwise.
  2. Spray tip clogged Refer to Clear Spray Tip Clog , page 25.

From 3A6342 rev G, page 37

Motorrunsbutpumpdoes not stroke
  1. Displacement pump pin damaged or missing; see pump manual. Replace pump pin if missing. Be sure retainer spring is fully in groove all around connecting rod; see pump manual.
  2. Connecting rod assembly damaged; see pump manual. Replace connecting rod assembly; see pump manual.
  3. Gears or drive housing damaged. Inspect drive housing assembly and gears for damage and replace if necessary; see pump manual.

From 3A6342 rev G, page 37

• Sprayer does not run at all • Display is blank • BlueLink status light never lights up
  1. Multiple electrical issues. See flow chart, page 46.

From 3A6342 rev G, page 39

Sprayer will not shut off
  1. Multiple electrical issues. See flow chart, page 48.

From 3A6342 rev G, page 39

• Sprayer does not run at all • Display shows CODE 02 • BlueLink status light blinks 2 times repeatedly
  1. Transducer or transducer connection issue. 1. Make sure there is no pressure in the system (see Pressure Relief Procedure , page 18). Check fluid path for clogs, such as clogged filter. 2. Use airless paint spray Hose with no metal braid 1/4 in. x 50 ft minimum. Smaller Hose or metal braid Hose may result in high-pressure spikes. 3. Set sprayer to OFF and disconnect power to sprayer. 4. Check transducer and connections to control board. 5. Disconnect transducer from control board socket. Check that transducer and control board contacts are clean and secure. 6. Reconnect transducer to control board socket. Connect power, set sprayer ON and control knob 1/2 turn clock - wise. If sprayer does not run properly, set sprayer to OFF and go to next step. 7. Install new transducer. Connect power, set sprayer ON and control knob 1/2

From 3A6342 rev G, page 39

• Sprayer does not run at all • Display shows CODE 03 • BlueLink status light blinks 3 times repeatedly
  1. Transducer connection issue (control board is not detecting a pressure signal). 1. Set sprayer to OFF and disconnect power to sprayer. 2. Check transducer and connections to control board. 3. Disconnect transducer from control board socket. Check to see if trans - ducer and control board contacts are clean and secure. 4. Reconnect transducer to control board socket. Connect power, set sprayer ON and control knob to 1/2 turn clock - wise. If sprayer does not run, set sprayer to OFF and go to next step. 5. Connect a confirmed working trans - ducer to control board socket. 6. Set sprayer ONandcontrol knob to 1/2 turn clockwise. If sprayer runs, install new transducer. Replace control board if sprayer does not run. 7. Check transducer resistance with ohm - meter (less than 9k ohm between red and black wires and 3-6kohm between green and yellow wires).

From 3A6342 rev G, page 39

• Sprayer does not run at all • Display shows CODE 4 • BlueLink status light blinks four times repeatedly
  1. Control board detected voltage surges. Set sprayer to OFF and disconnect power to sprayer. Locate a good voltage supply to prevent damage to electronics.

From 3A6342 rev G, page 40

• Sprayer does not run at all • Display shows CODE 05 • BlueLink status light blinks 5 times repeatedly
  1. Control is commanding motor to run but motor shaft does not rotate. 1. Remove pump and try to run sprayer. If motor runs, check for locked or frozen pump or drive train. If sprayer does not run, continue to step 2. 2. Set sprayer to OFF and disconnect power to sprayer. 3. Remove motor cover. 4. Disconnect motor connector(s) above motor. Check that connectors are clean. Reconnect connectors. Check that connectors are fully seated and secure. 5. Set sprayer to OFF and spin motor fan 1/2 turn. Restart sprayer. If sprayer runs, replace control board. If sprayer does not run, continue to step 5. 6. Perform Spin Test: Test at large 4-pin motor field connector. Disconnect fluid pump from sprayer. Test motor by plac - ing a jumper across pins 1 & 2. Rotate motor fan at about 2 revolutions per sec - ond. Acogging resistance to motion should be felt at the fan. The motor should be replaced if no resistance is felt. Repeat for pin combinations 1 & 3 and 2 & 3. Pin 4 (the green wire) is not used in this test. If all spin test is posi - tive, continue to step 6. See connections on next page:

From 3A6342 rev G, page 40

• Sprayer does not run at all • Display shows CODE 06 • BlueLink status light blinks 6 times repeatedly
  1. Motor overheated NOTE: Motor must be cooled down for the test. 1. Keep sprayer in cooler location with good ventilation. Make sure motor air intake is not blocked. 2. Remove motor cover. Ensure fan is securely attached to motor shaft. 3. Check thermal switch connector (yel - low wires) above motor. 4. Disconnect thermal switch connector above motor. Make sure contacts are clean and secure. Measure resistance of the thermal switch. If reading is not correct, replace motor. Check Motor Thermal Switch: Unplug thermal wires. Set meter to ohms. Meter should read the proper resistance for each unit (see table below). - ti13140a

From 3A6342 rev G, page 43

• Sprayer does not run at all • Display shows CODE 08 • BlueLink status light blinks eight times repeatedly
  1. Incoming voltage too low for sprayer operation 1. Set sprayer to OFF and disconnect power to sprayer. 2. Remove other equipment that uses the same circuit. 3. Locate a good voltage supply to avoid damage to electronics.

From 3A6342 rev G, page 44

• Sprayer does not run at all • Display shows CODE 10 • BlueLink status light blinks 10 times
  1. Control board is over heating. 1. Make sure motor air intake is not blocked. 2. Make sure fan is securely attached to motor shaft. 3. Replace control board. 4. Replace motor.

From 3A6342 rev G, page 44

• Sprayer does not run at all • Display shows CODE 12 • BlueLink status light blinks 12 times repeatedly
  1. Excessive current protection enabled Cycle power on and off.

From 3A6342 rev G, page 44

• Sprayer does not run at all • Display shows CODE 15 • BlueLink status light blinks 15 times repeatedly
  1. Motor not spinning (no current to motor) 1. Set sprayer to OFF and disconnect power to sprayer. 2. Remove motor cover. 3. Disconnect motor control and inspect for damage at connectors. 4. Reconnect motor control. 5. Turn power on. If code continues, replace control board.

From 3A6342 rev G, page 44

Sprayer does not run at all
  1. BlueLink status light never lights up Verify correct voltage and grounded outlet connection
  2. Display is blank Check electrical connections and power outlet

From 309941 rev J

Paint does not come out of the Spray Gun
  1. There is a blockage in the pump Hose or Spray Gun Follow Clear Blockage in Hose or Spray Gun procedure

From 309941 rev J

Questions about your Graco Ultra Max II 1095?

← All machines